CE Shield Transfer Impedance
The CE Shield Transfer Impedance module calculates, as
the name implies, the transfer impedance of the shield using the physical
properties of the shield. The CE Shield Transfer Impedance module is enabled only
when a shielded cable configuration is selected from the Conductor module.

Shield
transfer impedance is an intrinsic property of the shield.
Unlike shielding effectiveness, which is a function of test setup and the
circuits connected to the wires inside the shield, is an independent figure of merit. Shield transfer
impedance directly affects the shielding effectiveness of the shield. In
general, lower values of shield transfer impedance produce higher shielding
effectiveness.
Several options are available for calculating shield
transfer impedance, depending on the information available. Once shield
transfer impedance has been calculated the bar below the Shield Transfer
button on the CE Analyst form is changed from red to green. More:
CE Shield Termination
|