Creating a New CE Analyst Project
When a new conducted emissions
analysis is initiated the CE model is built sequentially. The basic
steps are:
1. Enter
Frequency Range -- Enter the frequency range over which to analyze the circuit
for .
2.
Specify a CE Limit -- Input the limit against which to compare calculated
conducted emissions. Limits may be created using the Limit form when the
CE project is being built or may be loaded from file if built previously.
3.
Define parameters -- Enter the time-domain
characteristics of the circuit voltage and current waveforms. CE
Analyst converts the time-domain waveforms to their frequency domain
equivalent spectrums over the frequency range specified in step 1 above.
Previously saved source models may be loaded from file.
4. Build
Filter model -- Using the schematic capture
program that is built into CE Analyst build a schematic diagram of those
electrical components that lie between the Source and the Conductors.
components are selected from the Component Library. Enter values to match
the characteristics of the actual components used.
5.
Specify Conductor parameters -- Select the conductor configuration that most
closely matches the circuit under investigation. Eight different cable
configurations allow nearly all common to be
modeled.
6.
Define Shield construction, as applicable -- For shielded conductors enter the
parameters that define how the shield is constructed. These values are
used to calculate , which is
used in determining shielding effectiveness of the shield.
7.
Specify Shield Termination parameters, as applicable -- For each end of shielded
conductor select a termination method and enter parameters that define how the
termination is constructed.
8. Build
model -- Using the schematic capture
program build a schematic diagram of the electric circuit to which the
conductors are connected. Select components from the Component Library and
enter values to match the characteristics of the components used in the load
circuit of the system under investigation.
9.
Calculate and display conducted emissions -- With the information above entered,
CE Analyst calculates the current and voltage for each component in the
filter and load and at each end of the conductors. At the completion of
calculations voltage and current are displayed graphically or numerically by
simply selecting the desired observation point. More: