CS Bound -- Real-Time Level, Current/Voltage that is X dB above the current/voltage level developed when the voltage/current limit is applied across a Y ohm load.

Current

When the CS limit is voltage specified in units of Volts or dBuV, select this option to place an upper limit on the injected CS current that is proportional to the voltage specified in the CS Limit.  The current amplitude injected on the conductors will not exceed the level determined by the value in the text boxes and the value of the CS limit voltage at the frequency being evaluated.

There are two text boxes associated with this option for specifying the upper current boundary.  Enter in the first text box the level in dB by which the current is allowed to exceed the current that would develop if voltage equal to the CS limit were applied across the impedance entered in the second text box.

For example, if the value entered in the first text box is "6"and the value entered in the second text box is 50, the bound will read as follows, "Current that is 6.00E+00 dB above the current level developed when the voltage limit is applied across a 5.00E+01 ohm load."  If the voltage limit is 69 dBuV at 10 kHz, as it is for the MIL-STD-461E limit shown above, the maximum current that will be injected at 10 kHz, where the voltage limit is 69 dBuV, is calculated real-time as follows:

Since the CS114 limit voltage changes with frequency the upper bound for current will also change with frequency to "track" the voltage limit as specified.

Voltage

When the CS limit is current specified in units of Amps or dBuA, select this option to place an upper limit on the CS voltage injected that is proportional to the current specified in the CS Limit.  The voltage amplitude injected on the conductors will not exceed the level determined by the value in the text boxes and the value of the CS limit current at the frequency being evaluated.

There are two text boxes associated with this option for specifying the upper voltage boundary.  Enter in the first text box the level in dB by which the voltage is allowed to exceed the voltage that would develop if current equal to the CS limit were applied across the impedance entered in the second text box.

For example, if the value entered in the first text box is "10"and the value entered in the second text box is 100, the bound will read as follows, "Voltage that is 1.00E+01 dB above the voltage level developed when the current limit is applied across a 1.00E+02 ohm load."  If the current limit is 3.0 Amps at 50 kHz the maximum voltage that will be injected at 50 kHz, where the current limit is 3.0 Amps, is calculated real-time as follows:

If the CS limit current changes with frequency the upper bound for voltage will also change with frequency to "track" the current limit as specified.