CS Bound -- Real-Time Level
Select the Real-Time Level option to place an upper
bound on the injected signal when the CS analysis is running. The
Real-Time Level option uses the impedance of the device under
investigation at the frequency being evaluated when determining whether the
injected signal exceeds the specified upper bound. If the upper bound is
exceeded the injected current, if the limit is specified in terms of voltage, or
the injected voltage, if the limit is specified in terms of current, is reduced
so that the upper bound is not exceeded. More:
CS Bound -- Real-Time Level, Fixed
CS Bound -- Real-Time Level, Current/Voltage that is X dB above the current/voltage level developed when the voltage/current limit is applied across a Y ohm load.
|