CS Bound -- Real-Time Level, Fixed

Current

When the CS limit is voltage specified in units of Volts or dBuV the fixed upper bound is specified in units of Amperes.  Select this option to place an absolute upper limit on the CS current injected.  The current amplitude injected on the conductors will not exceed the level specified in the text box for all frequencies evaluated during the CS analysis.

Enter the upper bound current amplitude in Amperes in the text box.

Voltage

When the CS limit is current specified in units of Amperes or dBuA the fixed upper bound is specified in units of Volts.  Select this option to place an absolute upper limit on the CS voltage injected.  The voltage amplitude injected on the conductors will not exceed the level specified in the text box for all frequencies evaluated during the CS analysis.

Enter the upper bound voltage amplitude in Volts in the text box.

More:

CS Bound -- Real-Time Level, Current/Voltage that is X dB above the current/voltage level developed when the voltage/current limit is applied across a Y ohm load.

 