Shunt Injection

Select one of the shunt injection options when the CS signal is to be injected between two conductors.  Shunt injection is equivalent to connecting a signal generator between the two conductors at the injection point and driving a CS signal equivalent to the levels specified in the CS Limit module from one conductor to the other.

Not all shunt injection options are available for all conductor configurations.  Shunt injections options are:

High Line to Low Line

High Line to Ground

High Line to Shield

Low Line to Ground

Low Line to Shield

Ground to Shield